Inquiry #1: On Sheet 47, PDQ 1 of the plans it shows Detail 36A and Detail 36B quantities under the 4" Thermoplastic Stripe, White Solid and again under the 8" Thermoplastic Traffic Stripe, White Solid area. Also within the same plan page there are callouts for Detail 25M, and Detail 50 Mod, but there is no explanation as to what these details are.
Inquiry submitted 06/05/2014

Response #1:Your inquiry has been received and is being reviewed. Thank you for your patience.
Response posted 06/05/2014


Response #2:Detail 25M and Detail 50 are calculated for 1' buffer & 2' buffer as shown on the Pavement Delineation Plans. Detail 36A and Detail 36B are for striping at gore areas.


Response posted 06/06/2014




Inquiry #2: Section 39 in the Special Provisions are specifications for Caltrans Standard Specification 2010 Hveem Mix but bid item 32 HMA A and bid item 33 RHMA G and the plans indicated Superpave. Is this a superpave project? If so please provide the superpave specifiction for section 39.
Inquiry submitted 06/09/2014

Response #1:This is a superpave project and the specification are included on section 39 in the Special Provisions. The specs for superpave begins on page 69 on the Special Provision.


Response posted 06/09/2014




Inquiry #3: Section 39 in the Special Provisions are specifications for Caltrans Standard Specification 2010 Hveem Mix but bid item 32 HMA A and bid item 33 RHMA G and the plans indicated Superpave. Is this a superpave project? If so please provide the superpave specifiction for section 39.
Inquiry submitted 06/09/2014

Response #1:This is a superpave project and the specification are included on section 39 in the Special Provisions. The specs for superpave begins on page 69 on the Special Provision.


Response posted 06/09/2014




Inquiry #4: For Items# 42, 44, & 49 there is no detail or layout and for Items# 43 & 45 there is no layout. How are we to determine ends, corners, terminals for these items? Since Item# 49 is a Final Quantity there should be more information, layout, detail, etc. Please advise!
Inquiry submitted 06/10/2014

Response #1:Item 42 there is no drawn detail. Refer to specification under section 80-4 Wrought Iron Fence in the project specifications. Location is described in chart on sheet Q-8, intended to close the opening between freeway wall and the commercial building immediately to the west. The second location noted in the chart as 162' south of Olympic Blvd. should be corrected to 370' south of Olympic Blvd. The fence should close the gap between the freeway retaining wall and an existing block wall at the southern corner of the commercial parking lot adjacent.
Item 43 location is described in chart on sheet Q-8. Fence is intended to close the gap between parallel soundwalls. Fence should be perpendicular to the soundwalls.
Item 44 there is no drawn detail. Refer to specification under section 80-11 Wrought Iron Gate in the project specifications. The gates should be centered in the fence.
Item 45 gates should be centered within fence.
Item 49 detail is shown in Standard Plan sheet B11-47 on page 293 in the printed version of the 2010 Standard Plans. Location is described in chart on sheet Q-8, intended to close the opening between existing chain link railing and adjacent soundwall at north end of bridge.

Response posted 06/10/2014




Inquiry #5: What is the height for the Wrought Iron Fence & Gates?

Inquiry submitted 06/10/2014

Response #1:The height of the wrought iron fence and gates should be 6'.
Response posted 06/10/2014




Inquiry #6: What is the width of the wrought iron gates? Are they swing or rolling gate?
Inquiry submitted 06/10/2014

Response #1:The wrought iron gates will be 4' wide each for a total opening of 8'. They should swing open.
Response posted 06/11/2014




Inquiry #7: What's the width of the wrought iron gates? Are they swinging or rolling gates?
Inquiry submitted 06/11/2014

Response #1:The wrought iron gates will be 4' wide each for a total opening of 8'. They should swing open.
Response posted 06/11/2014




Inquiry #8: Reference to answer to inquiry #4, Item #49 should be per 2010 Standard Plan B11-47, these detail is for Cable Railing and not Chain Link Railing (Type 7), please clarify which one to use. Thanks
Inquiry submitted 06/11/2014

Response #1:Use Chain link railing detail B11-7.
Response posted 06/11/2014






The information provided in the responses to bidder inquiries is not a waiver of Section 2-1.03, “Examination of Plans, Specifications, Contract, and Site of Work,” of the Standard Specifications or any other provision of the contract, nor to excuse the contractor from full compliance with the contract. Bidders are cautioned that subsequent responses or contract addenda may change a previous response.