Inquiry #1: On Electrical Dwg E-2, The location of the flashing beacons are drawn at 400'. Are they drawn in the wrong place, or is the 500' marking wrong?
Inquiry submitted 08/30/2013

Response #1:Submitted for consideration.
Response posted 09/03/2013


Response #2:The marking is incorrect and should state "400' TO LIMIT LINE".
Response posted 09/03/2013




Inquiry #2: On the plans for Location 2, and the quantity sheet Q-1 (under Roadway Quantities), it shows Cold Plane AC, with HMA cross slope change. The typicals on sheet SC-3, have no mention of either of these, Which are correct?
Inquiry submitted 09/03/2013

Response #1:The L-2 Layout sheet and X-5 Typical Cross Section sheet are correct in showing the cross slope correction.
Response posted 09/05/2013




Inquiry #3: Should not Bid Item No. 6 be in SF and not in LF ?
thanks

Inquiry submitted 09/06/2013

Response #1:Submitted for consideration.
Response posted 09/09/2013


Response #2:Contractor is correct, it should be SF.
Response posted 09/10/2013




Inquiry #4: Please clarify bid item #49 - Reset Temporary Railing (Type K) Does this item only include the resetting of the rail to the shoulder as shown on TH 19-22 for the winter shut down, or does it also include the resetting after the winter shut down, back to where it was?
Inquiry submitted 09/16/2013

Response #1:Submitted for consideration.
Response posted 09/17/2013


Response #2:Submitted for consideration.
Response posted 09/17/2013


Response #3:Item for Resetting the k-rail for winter shutdown is a two way reset. It requires moving the K-rail (during the winter season) away from where originally were placed, and then resetting them back to their original location.
Response posted 10/01/2013




Inquiry #5: Takeoff shows a large under-run for item 104. Using the areas given on sheet 193 for the slope paving and the thickness given on sheet 43 gives a large under-run as well. Will Caltrans issue an addendum to change the bid quantity?
Inquiry submitted 09/18/2013

Response #1:Submitted of consideration.
Response posted 09/19/2013


Response #2:See Addendum 3.
Response posted 04/22/2014




Inquiry #6: Bid item #66 has the quantity of 230 cy for ATPB. The table on Q-1 shows 126 cy on Mainline (which is correct) and 102 cy on Watsonville Rd, but the typical section on sheet X-15 for Watsonville Road does not show ATPB. Please correct.
Inquiry submitted 09/19/2013

Response #1:Submitted for consideration.
Response posted 09/20/2013


Response #2:See Addendum 3.
Response posted 04/22/2014




Inquiry #7: ITEM #115, CONCRETE BARRIER, TYPE 60C MODIFIED:
Plan sheet 42, C-6,details the 60C Mod. as 36 inches both above and below offset road surface, and also as "varies". Which is correct? If the answer is "varies", please provide cross sections or details giving the varying offset dimensions.
Plan Typical Cross Section sheets 3-12, X-2 to X-12, show the CB60C MOD. on structural section totally above the offset road surface.
What is the correct detail and dimensioning?

Inquiry submitted 09/25/2013

Response #1:Submitted for consideration.
Response posted 09/25/2013


Response #2:See Addendum 3.
Response posted 04/22/2014




Inquiry #8: The Special Provisions added Section 12-3.16J Temporary 6' Chain Link Fence (Type CL-6) and Section 12-3.16K Temporary 4' Chain Link Gate (Type CL-6).
The Bid Item List does not include bid items for temporary fence and/or gates, nor is any temporary chain link fence and gates located on the project plans.

* Please clarify if Temporary 6' Chain Link Fence (Type CL-6) is required for this project.

* Please clarify if Temporary 4' Chain Link Gate (Type CL-6) is required for this project.

If so, please provide bid item information for bidding.

Inquiry submitted 09/25/2013

Response #1:Submitted for consideration.
Response posted 09/26/2013


Response #2:Section 12-3.16A GENERAL, paragraphs 1 and 2 describes the bid item related to Temporary Signal Systems. Temporary Chain link fence and gates are included in the description of this bid item.

Contractor should also take note of Section 9-1.03 Payment Scope in the Standard Specifications as it relates to this item.

Temporary Chain Link Fence and Gates are shown on Sheets E-26 and E-31.

Response posted 09/30/2013




Inquiry #9: Will the project be shut down with no construction activity from October 15 to April 15. If not what opperations are allowed. Are the days during the seasonal shutdown (oct 15 - April 15)counted as working days.
Inquiry submitted 09/30/2013

Response #1:Submitted for consideration.
Response posted 10/01/2013


Response #2:Please see Addendum 3, dated April 3, 2014, Replaced Special Provisions Section 14-6.02C(4) “Protection Measures” which identifies allowable work windows and restrictions.
Response posted 04/11/2014




Inquiry #10: Reference plan sheet SC-1. Must sequence A be complete before the start of sequence B and sequence B complete before the satrt of sequence C?
Inquiry submitted 09/30/2013

Response #1:Submitted for consideration.
Response posted 10/01/2013


Response #2:Please see Addendum 3, dated April 3, 2014, Replaced Sheet SC-1 for further clarification and updated sequence of staging.
Response posted 04/11/2014




Inquiry #11: Bid Item #121 calls for 640 SQFT of Paint Pavement Markings (-Coat), where are these markings on the plans and where are they in the quantities?
Inquiry submitted 10/03/2013

Response #1:Submitted for consideration.
Response posted 04/22/2014


Response #2:Item No. 121 has been deleted. Please see Addendum 6.
Response posted 04/24/2014




Inquiry #12: Sheet 228 (E-30) lists 80 LF of chain link fence (CL-6) and one 4' chain link gate (CL-6) under Temporary Signal System (Location 3). The Bid Schedule does not list a bid item for Temporary Signal System for Location 3.

Please revise the bid schedule to include a bid item for Temporary Signal System at Location 3.

Inquiry submitted 04/03/2014

Response #1:Submitted for consideration.
Response posted 04/04/2014


Response #2:Please see Addendum 3, dated April 3, 2014, refer to Bid Item No. 127 “TEMPORARY SIGNAL SYSTEM (LOCATION 3)”.
Response posted 04/11/2014




Inquiry #13: Addendum No. 3:
Sec. 80-7 Temp. Fence, Type FROG, is there a pay item for this fencing ?
Sec. 39-1.12A General, Inertial Profiler & Straightedge, it there a pay item for this work ?

Inquiry submitted 04/08/2014

Response #1:Submitted for consideration.
Response posted 04/08/2014


Response #2:Submitted for consideration.
Response posted 04/08/2014


Response #3:a) Please see Addendum 3, dated April 3, 2014, refer to Bid Item No. 128 “TEMPORARY FENCE (TYPE FROG)”.

b) No, it's part of a Contractor's quality control . However, please see Addendum 3, dated April 3, 2014, refer to Bid Item No. 135 “PREPAVING INERTIAL PROFILER” as indentified in added Special Provisions Section 39-1.12G .
Response posted 04/11/2014




Inquiry #14: Sheet 416G shows a bearing pad and polystyrene on top of each of the soldier piles. Is there a plate that is welded to the tops of the piles to support these similar to other projects? Please provide the detail as to how the bearing pad and polystyrene is supported.
Inquiry submitted 04/16/2014

Response #1:Submitted for consideration.
Response posted 04/17/2014


Response #2:Unless an addendum is issued addressing your concern, please bid per the current contract bid documents.
Response posted 04/23/2014


Response #3:Please see revised plan sheet 416G and section 49-4.02 of Addendum No. 6 dated April 24, 2014.
Response posted 04/25/2014




Inquiry #15: Refering to the Structural Detail Sheet 1's (sheet 251 as an example) and Special Conditions for Section 75 Miscellaneous Metal:
1) Is there a reason the drawing uses Imperial dimensions and the Special Conditions refer to the metric version of F 738?
2) Do these Safety hooks occur in any locations other than Soil Nail Walls 1, 2, 3, 4, 7, 8, 9, 10, and 11? My weight differs from the bid item estimate substantially and I am wondering if my count is incorrect.

Inquiry submitted 04/21/2014

Response #1:Submitted for consideration.
Response posted 04/22/2014


Response #2:1) Is there a reason the drawing uses Imperial dimensions and the Special Conditions refer to the metric version of F 738?

    Please see section 75 in Addendum No. 6 dated April 24, 2014.


2) Do these Safety hooks occur in any locations other than Soil Nail Walls 1, 2, 3, 4, 7, 8, 9, 10, and 11? My weight differs from the bid item estimate substantially and I am wondering if my count is incorrect.
    The safety hooks only occur in Soil Nail Wall Nos. 1, 2, 3, 4, 7, 8, 9, 10, and 11. The quantity is correct. Please bid per the current contract documents.

Response posted 04/25/2014




Inquiry #16: Items 117, 118, 119, and 120 on the bid items list calls for the installation of the Thermoplastic with no indication it is to be Wet/Night Enhanced. However in the Special Provisions, Sec 84-601 it gives the standard for Wet/Night Enhanced. Is it Caltrans' intent to install the thermoplastic delineation at the Wet/Night Enhanced Spec?
Inquiry submitted 04/24/2014

Response #1:Submitted for consideration.
Response posted 04/25/2014


Response #2:Thermoplastic pavement striping/ marking items are to be installed as stated in the special provisions and the standard specifications.
Response posted 04/28/2014




Inquiry #17: In addendum 3 on page 32 of 44 it seems to state that Natina will be applied at an enclosed shop and also asks for a paint cert of some kind. We are the manufacturer of this product and it is never applied in an enclosed shop and is typically applied by us (not a painting contractor), outdoors, at our facility. I don't want bids to be rejected because they do not include a bid to do this work at an enclosed shop by a painting contractor. please advise.
Inquiry submitted 04/24/2014

Response #1:Submitted for consideration.
Response posted 04/25/2014


Response #2:Section 59-2 is related to PAINTING STRUCTURAL STEEL while Section 59-11 is related to STAINING GALVANIZED SURFACES.

Section 59-11.02 of Addendum 3 was related to the updated cost information of the Natina Staining.

Response posted 04/28/2014


Response #3:Section 59-9 is specification requirements for painting steel soldier piles. Section 59-11 is specification requirements for staining galvanized surfaces (Natina). In Addendum No. 3, Section 59-9.01 only applies to painting steel soldier piles.
Response posted 04/29/2014






The information provided in the responses to bidder inquiries is not a waiver of Section 2-1.03, “Examination of Plans, Specifications, Contract, and Site of Work,” of the Standard Specifications or any other provision of the contract, nor to excuse the contractor from full compliance with the contract. Bidders are cautioned that subsequent responses or contract addenda may change a previous response.